Publish:Shenzhen City Jia Hong Wei Technology Co., Ltd. Time:2016-11-09
590 governor repair case
Customer: a container manufacturing company in Huizhou
Steel plate shearing equipment
Model: Continental 590P speed
Fault causes: on the electricity to run PULSE MISSING alarm
Fault analysis: 590 customers in steel plate shear feeding governor is used, according to the customer‘s fault prompt is alarm occurs at startup, fault of six pulse armature current loss of a pulse waveform, the motor load is more than 1.5 times the DISCONTINUOUS (discontinuous point) value, start the alarm. Fault causes are: harmonic interference, trigger board fault, plug loose, controlled silicon damage. After the measurement of the external fault to the governor of the drive to measure the output waveform at run time has obvious asymmetry. Measurement of the drive circuit to exclude the motherboard problem for the control of silicon measurement, the power on line measurement found that the drive IC is damaged. Replacement with load test after lifting.
590 European governor alarm may cause
Accts failed missed the current transformer fault current transformer
Abort Autotune automatic tuning failure automatic tuning extended out of flexibility
Automatic tuning error of Errot Autotune automatic tuning error
Power fail AUX auxiliary power failure assisted self inspection to the problem
Fail Checksum (Eeprom) verification and failure
Config Enable configuration is effective to select the effective state
Failed Encoder encoder fault encoder signal fault
Alarm Encoder encoder alarm
Fail Field excitation fault excitation current is too low
Excitation current of over Field 1 excitation over current motor
Word Health normal word
Store Health normal storage
Trip Heatsink radiator overheating trip radiator overheated
FBK CAL fail IA armature current self-test failure
Inst CAL fail IA armature current self-test failure
Checksum fail Language language to choose the wrong way
Pluse Missing missing pulse missing armature current pulse
I trip Over over current tripping motor armature over current
Speed Over speeding motor
Volts Over overvoltage motor armature overvoltage
Lock Phase phase locked loop AC synchronous failure
Fault Pre-Peady prepared to lack
State P3 P3 port status warning
FBK alarm Speed speed feedback alarm
Trip Stall blocking switch trip motor blocking time out trip
Thermistor thermistor motor overheating
Reset Trip trip reset
Failed 3-Phase 3 phase fault No 3 phase power supply
Hong Jia Wei maintenance continental DC-master EUROTHERM common faults such as: no display, overcurrent, undervoltage, overvoltage, overheating, grounding, parameter error, alarm, thyristor breakdown, no excitation, jitter. EUROTHERM DC maintenance range:
IS3 series, SSD590 series, SSD591 series, SSD590+ series, SSD590C, SSD590P, SSD512C, SSD514C series.
Jia Hong professional maintenance of the following DC speed regulator brand:
SIEMENS, Continental, and ABB, Lentz, Fuji, MITSUBISHI, Toshiba, 100 Benguela, Yaskawa, Hitachi, AB, Emerson, Sanken, Danfoss, Delta, Taian, Samsung, LG, Michael, Matsushita, Viking, Te Luth Le, Dr. Baumiller Rexroth, etc.
Jia Hong Wei repair service hotline: 0755-28916839, 13640994287 Shaw