KOMORI printing equipment maintenance case
Client: Buji, Shenzhen, on a printing factory
Device: KOMORI KOMORI
Printing machine
Fault phenomenon: the power PLC controller has a signal but the main motor does not turn.
Fault analysis: This equipment for the old original Japanese KOMORI printing machine view line is basically intact. Customer reaction is still able to work in the morning to the normal operation of this fault occurs in the afternoon. The PLC controller has an output signal in the start of the test. The main motor is controlled by PLC to signal control. Host control for SANYO VF64 variable frequency drive, but the encoder is closed loop control. Printing machine a start-up frequency converter alarm "OC" to explain the fault problem in the host motor inverter. The investigation of frequency converter
Output module and drive W phase damage.
Failure repair: replacement of the inverter module
W driver, capacitor. Power up again.