Schneider servo driver maintenance

You are here:Home >> Program >> Servo repair >> Schneider servo dr...
臺(tái)達(dá)PLC AS3解密
Name:Delta B2 servo drive
Model:臺(tái)達(dá)B2
 Delta B2 servo driver maintenance - Hong Jia Wei maintenance fault repair deltaservo ASD-A2, ASD-B2, ASD-A+, ASD-A2-L, ASD-AB and other delta server: no display, lack of phase, overcurrent, overvoltage, undervoltage, overheating, overload, grounding, parameter error, output module, display without damage; please you dial service hotline 0755-28916839, 13640994287, we have professional customer service staff to quickly respond to your needs.
Description
 Delta B2 servo drive
Model: ASD-B20721
Failure phenomenon: AL001 alarm (over current)
Fault analysis: according to the fault description for the customers to work just start spraying reciprocating machine appeared AL001 alarm from other devices installed on the same drive down OK, according to the description of the fault is recognised as servo drive failure. Open the case to check the power supply is normal. Measurement of the main circuit IGBT module U and P have a short circuit phenomenon. Remove the module to measure the driving voltage is normal. The initial suspicion is that the short circuit of the IGBT module leads to the failure of the AL001 fault. The replacement of the new module on the electrical test paper AL011 fault. Connect motor and encoder test everything to normal.
Fault repair: replacement of the new IGBT module fault repair.
Hong Jia Wei maintenance common fault repair deltaservo ASD-A2, ASD-B2, ASD-A+, ASD-A2-L, ASD-AB and other delta server: no display, lack of phase, overcurrent, overvoltage, undervoltage, overheating, overload, grounding, parameter error, output module, display without damage;
Jia Hong Wei repair service hotline: 0755-28916839, 13640994287 Shaw